Search results for "Acid Etching"
showing 10 items of 14 documents
Applications of confocal laser scanning microscopy to dental bonding.
1998
The introduction of confocal laser scanning microscopy (CLSM) has provided a valuable new technique for the visualization of bonding structures such as a hybrid layer in dentin (Watson, 1989, 1991), In the case of seven commercially-available dentin bonding systems, it could be demonstrated that the CLSM renders considerably more detailed information than the SEM because of its nondestructive nature and because of the possibility of a distinction between components of bonding agents. With most of the bonding systems, measurements of the thickness of the hybrid layer could be carried out when the primer component was labeled with rhodamine B. It was found that this thickness is significantl…
How can droplet formation occur in endodontically treated teeth during bonding procedures?
2008
PURPOSE: The aim of this in vivo study was to clarify how blistering formation occurs along intraradicular dentin bonded interfaces. MATERIALS AND METHODS: Patients were selected and post space was prepared in vivo in endodontically treated teeth. Post space was etched, dried with ethanol, and bonded with one of the following adhesive systems: All Bond 2, XP-Bond, Clearfil SE Bond, Xeno III. The four adhesives were considered as representative of each bonding system class. An additional group was prepared with phosphoric acid treatment + application of Pre-Bond unfilled resin of All Bond 2, without the use of the primer agent. Etching was avoided for self-etching materials. Replicas of the …
Production of bone mineral material and BMP-2 in osteoblasts cultured on double acid-etched titanium
2017
Background: The study of osteoblasts and their osteogenic functions is essential in order to understand them and their applications in implantology. In this sense, this study try to study BMP-2 production and bone matrix deposition, in addition to other biological variables, in osteoblasts cultured on a rough double acid-etched titanium surface (Osseotite®, Biomet 3i, Palm Beach Garden, Florida, USA) in comparison to a smooth titanium surface (machined) and a control Petri dish. Material and Methods: An in vitro prospective study. NHOst human osteoblasts from the femur were cultured on three different surfaces: Control group: 25-mm methacrylate dish (n = 6); Machined group: titanium discs w…
In vitro comparison of the retention capacity of new aesthetic brackets.
1999
Tensile bond strength and bond failure location were evaluated in vitro for two types of aesthetic brackets (non-silanated ceramic, polycarbonate) and one stainless steel bracket, using bovine teeth as the substrate and diacrylate resin as the adhesive. The results show that metallic bracket had the highest bond strength (13.21 N) followed by the new plastic bracket (12.01 N), which does not require the use of a primer. The non-silanated ceramic bracket produced the lowest bond strength (8.88 N). Bond failures occurred mainly between bracket and cement, although a small percentage occurred between the enamel-cement interface with the metal and plastic brackets and within the cement for the …
Sealing capacity of a photochromatic flowable composite as protective base in nonvital dental bleaching.
2006
Aim To evaluate microleakage of a flowable composite used as a protective isolating base, applied with different adhesive systems. Methodology Seventy root-filled teeth were divided into seven groups. A flowable composite base (Tetric Flow Chroma) was used with three adhesive techniques (Syntac, Excite, Excite DCS; in the three cases with and without acid etching) and in a control group without dentine conditioning or adhesive placement. A 30% hydrogen peroxide solution was applied for 24 h in the pulp chambers, followed by the placement of a dye (silver nitrate) for 4 h. Each tooth was sectioned longitudinally, and examined under 4× magnification to assess the tooth/restoration dye leaka…
Marginal integrity of class V restorations: SEM versus dye penetration.
2006
To perform an in vitro investigation on the marginal integrity of different adhesives (Optibond FL, Scotchbond 1XT, Clearfil SE Bond, Adper Prompt L-Pop, S(3) Bond, iBond exp., Adper Prompt L-Pop) in combination with Tetric Ceram as well as an experimental silorane-restorative (Hermes, Hermes Bond; 3M ESPE) using SEM and dye penetration (2% methylene blue) in a comparative manner.Standardized class V-cavities (3 mm x 1.5 mm) were prepared in 70 extracted human teeth (n=10). The adhesives were applied according to manufacturers' instructions. The cavities were restored with three increments. After finishing and polishing (Sof-Lex discs) and thermocycling (5000x, 5/55 degrees C), replicas wer…
Surface debris of canal walls after post space preparation in endodontically treated teeth: A scanning electron microscopic study
2004
Abstract Purpose To evaluate surface cleanliness of root canal walls along post space after endodontic treatment using 2 different irrigant regimens, obturation techniques, and post space preparation for adhesive bonding. Study design Forty teeth, divided into 4 groups, were instrumented, using Ni-Ti rotary files, irrigated with NaOCl or NaOCl + EDTA and obturated with cold lateral condensation (CLC) or warm vertical condensation (WVC) of gutta-percha. After post space preparation, etching, and washing procedure, canal walls were observed using a scanning electron microscope (SEM). Amount of debris, smear layer, sealer/gutta-percha remnants, and visibility of open tubules were rated. Result…
Bactericidal Effect of the Er:YAG Laser on Dental Implant Surfaces: An In Vitro Study
2002
The aim of the in vitro study was to examine the bactericidal effect of an Er:YAG laser on common dental implant surfaces.Seventy-two titanium platelets with 3 different surfaces--sandblasted and acid-etched (SA), titanium plasma-sprayed (TPS), and hydroxyapatite-coated (HA)--were incubated with a suspension of Streptococcus sanguinis (ATCC 10556). Irradiation at pulse energies of 60 and 120 mJ and a frequency of 10 pps was performed on a computer-controlled XY translation stage. After laser treatment the specimens were sonicated and the bacterial growth examined by counting colony forming units on blood agar plates. Temperature elevations during irradiation were investigated using K-type t…
POSITIONING SELF-ETCHING ADHESIVES: VERSUS OR IN ADDITION TO PHOSPHORIC ACID ETCHING?
2004
Some morphologic changes induced by Nd:YAG laser on the noncoated enamel surface: A scanning electron microscopy study
1992
The enamel surface layer of some human teeth was treated with the low-energy Nd:YAG laser at 8 mJ pulse energy. These samples were previously etched with 0.05 M orthophosphoric acid to reduce the surface reflection. The treated samples, as well as the control samples, were widely studied by scanning electron microscopy, and, in the lased group, significant morphologic changes affecting the enamel surface were observed. Those changes reveal principally the loss of the typical surface structure of the acid-etched enamel. The hydroxyapatite prisms were not discernible, and there was a decrease in the roughness of the lased surface enamel. These laser-induced structural changes may be related t…